EC6 Radon Fan Technical Information
EC6 Radon Fan Performance Data and Curves
| Typical CFM vs. Static Pressure |
|||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | P/N | Fan Duct Diameter | Watts | Recommended Max Operating Pressure "WC | 0" | 0.2" | 0.5" | 1.0" | 1.5" | 2.0" | 2.5" | 3.0" | 3.5" | 4.0" | 4.5" |
| EC6 | 28625 | 6" | 140-175 | 4.25 | 514 | 490* | 451 | 381 | 330 | 271 | 211 | 152 | 101 | 49 | - |
| 4"** | 112-175 | 4.75 | 341 | 330 | 304 | 271 | 239 | 204 | 175 | 137 | 87 | 49 | 31 | ||
*HVI Certified Value. **Using 6"x4" reducing coupling.